© 2014 Mold-Masters (2007) Limited. All Rights Reserved.
Revised 1 Oct, 2014
E-11
SEQUENCE VALVE GATE
Setting up examples
Each valve gate can have up to 4 steps. The valve will act according
to these step settings. A step consists of opening and closing the valve
gate. The following are various scenarios for operating a valve during
a sequence:
Opening and closing the gate on time values alone
Open the valve on an absolute time (relative to the start of the cycle)
and close it on an absolute time value (relative to the start of the cycle)
Open the valve on an absolute time (relative to the start of cycle) and
close it on at incremental time (relative to the when the valve was
opened)
Opening and closing the gate on screw position
alone
Open the valve on screw position and close it on the screw position.