Engine
SHOP MANUAL MT26-31 - 06.2005
Tier-3 710655-
Ch 1 page 23
Example to change temp alarm and warning:
Go to S6 ---> E2 ---> Program E2 parameter.
Read values.
Go to the column for values,
find the line for engine temp and change the value.
Then go to the "button" ; write values and click on it,
the value will now be change.
Confirm your choise