Issue 2.0
8-58 IP Multiline Station (SIP)
84-23-11
DT800/DT700
Multiline Basic
Information Setup –
Password Lock
Time
Time to leave the terminal Locked
Out after entering the wrong security
code.
Range; 0 ~ 120
Default: 0
Default is 0
X
84-23-12
DT800/DT700
Multiline Basic
Information Setup –
Reference Number
Assign the network admin telephone
number. When the user presses the
Call key to contact the network
administrator, this number is dialed.
Up to 32 Digits
(0~9, *, #, P, R, @)
Default is No Setting
X
84-23-13
DT800/DT700
Multiline Basic
Information Setup –
Media Type of
Service
Assign the IP terminals MEDIA TOS
values.
Range: 0x00 ~ 0xFF
(0~9, A~F)
Default is 00
X
84-23-14
DT800/DT700
Multiline Basic
Information Setup –
Refer Expire Timer
The valid period of the REFER
subscription.
Range: 0 ~ 65535 Sec.
Default is 60
X
84-24-01
DT800/DT700
Multiline CODEC
Basic Information
Setup –
Number of G.711
Audio Frames
Amount of audio in each RTP
packet.
Range: 1~4
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
Default is 2
X
84-24-02
DT800/DT700
Multiline CODEC
Basic Information
Setup –
G.711 Voice Activity
Detection
Enable/Disable VAD for G.711
0 = Disable
1 = Enable
Default is 0
X
84-24-03
DT800/DT700
Multiline CODEC
Basic Information
Setup –
G.711 Type
-law used in N.A.
0 = A-law
1 = -law
Default is 0
X
84-24-04
DT800/DT700
Multiline CODEC
Basic Information
Setup –
G.711 Jitter Buffer
Minimum
Minimum value of the dynamic jitter
buffer.
Range: 0 ~ 300ms
Default is 20
X
Program
Number
Program Name Description/Comments Assigned Data 1 2 3