SV9100 Networking Manual 8-57
84-23-03
DT800/DT700
Multiline Basic
Information Setup –
Session Expire
Timer
At half the value of this timer the IP
terminal sends a re-invite message.
Range: 60~65535 Sec.
Default is 180
X
84-23-04
DT800/DT700
Multiline Basic
Information Setup –
Minimum Session
Expire Timer
Minimum time the CPU accepts a
session timer for a new call.
Range: 60~65535 Sec.
Default is 180
X
84-23-05
DT800/DT700
Multiline Basic
Information Setup –
Invite Expire Timer
When INVITE message received
from SIP MLT does not contain
Expires header, the CPU uses this
value for timeout of outgoing call.
E.g. The SIP MLT hears RBT for
duration of this timer and then is
disconnected.
Range: 0~65535 Sec.
Default is 180
X
84-23-06
DT800/DT700
Multiline Basic
Information Setup –
Signal Type of
Service
Used for updating the IP terminals
SIGNALING TOS values.
Range: 0x00 ~ 0xFF
Default is 00
X
84-23-07
DT800/DT700
Multiline Basic
Information Setup –
Error Display Timer
The time that an IP terminal holds
an error message in the display.
Setting 0 holds the error message
indefinitely.
Range: 0 ~ 65535 Sec.
Default is 0
X
84-23-08
DT800/DT700
Multiline Basic
Information Setup –
Digest Authorization
Registration Expire
Timer
When Digest Authentication mode is
ON, this value is available.
After receiving Initial INVITE without
authentication information, CPU will
send 401 message to the SIP MLT,
then waits for an INVITE message
with the authentication message
from SIP MLT within this timer.
Additionally, after receiving Re-
REGISTER message for Keep Alive
purpose, the CPU sends a 401
message.
Range: 0 ~ 4294967295
Default is 0
X
84-23-10
DT800/DT700
Multiline Basic
Information Setup –
Number of
Password Retries
The number of times an incorrect
password can be entered when the
security key is pressed.
If set to (1), only one attempt is
allowed. When number of password
retries is met an error message
displays on the phone: Incorrect
security code password entered,
press call key to contact an
administrator
Range: 0 ~ 255
Default is 0