EasyManua.ls Logo

NEC Univerge SV9100 - Page 755

NEC Univerge SV9100
766 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 2.0
13-160 AspireNet
18
Silence Compression (VAD)
Threshold
Set the voice level judged to be
silence.
Change value based .30
This entry is ignored if silence
compression is disabled in 84-01-
03 with G.711, or 84-01-06 with
G.729.
0-30
(self-adjustment and
-19db ~ +10db)
0 = self-adjustment
1:-19db (-49dbm)
:
20 = 0db (-30dbm)
:
29 = 9dbm (-21dbm)
30:10dbm (-20dbm)
20
19
Idle Noise Level
Set the noise level which is
generated when silent.
5000-7000
(-5000 ~ -7000dbm)
5000 = -5000dbm
:
7000 = -7000dbm
7000
20
Echo Canceller Mode
Determine whether or not to use
Echo canceller.
0 =Disable
1 =Enable
1
21
Signal limiter
Set the Signal Limiter Mode.
1 =Mode0
2 =Mode1
3 =Mode2
4 =Mode3
5 =Mode4
6 =Mode5
6
22
Echo Canceller NLP Mode
Non-linear processing mode.
Enable this option to decrease the
low level echo. When NLP is
enabled, the voice with low level is
replacecd with NLP noise. As a
result, a low echo of the level is
usually removed compared with the
conversation level.
0 =2 wire & 4 wire
1 =2 wire only
1
23
--- Not Used ---
24
Echo Canceller NLP Noise
Setting
Becomes invalid item if 84-12-22 is
set to Disabled.
Set the noise level adjusting
method added with NLP.
When “0” is set, the level is self-
adjusted - when “1” is set, Program
84-13-23 is used.
0 =adaptive
1 =fixed
0
25
- Not Used -
-
-
Input Data
Ite
m
No.
Item Input Data Default