4-16 Features and Specifications
Trunk-to-Trunk Transfer must be allowed in PRG 14-01-13 for each trunk
(Trunk-to-Trunk Transfer Yes/No Selection).
A Single Line Telephone user can transfer a trunk call to another internal station
that is set for Call Forwarding – All Calls - K-CCIS, however, when the distant
party answers the call, a conference cannot be established.
The destination station in the distant systems is the only station that can call a
station with Call Forwarding – All Calls – K-CCIS set.
Call Forwarding with Both Ringing (All Calls) is not supported.
Call Forward Split Internal/External is not supported.
Forwarding to Voice Mail is not Included in the Maximum Hop Count.
Call Forward continues to operate to a D
term
that has been removed.
RELATED FEATURE LIST
Call Forwarding – Busy/No Answer – K-CCIS
Multiple Call Forwarding – All Calls – K-CCIS
Multiple Call Forwarding – Busy/No Answer – K-CCIS
Link Reconnect – K-CCIS
Uniform Numbering Plan – K-CCIS
Guide to Feature Programming
This guide provides a list of associated Programs that support this feature.
Program/
Item No.
Description/
Selection
Assigned Data Comments
20-11-12 Class of Service Options
(Hold Transfer Service) –
Call Forwarding
Off-Premise (External Call
Forwarding
0 = Off
1 = On
Default is 0
To enable per class of service.
20-06-01 Class of Service for
Extensions
0~15 Ext.101 is in Class 15. All others are in Class
1.(default)
20-09-07 Class of Service Options
(Incoming Call Service) –
Call Queuing
0 = Off
1 = On
Default is 0
Must be Off for Call Forward – Busy to operate.
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off Hook
Signaling (Automatic
Override)
0 = Off
1 = On
Default is 1
Must be Off for Call Forward – Busy to operate.

Table of Contents

Other manuals for NEC Univerge SV9100

Related product manuals