Virtual Private Networking Using IPSec and L2TP Connections
267
NETGEAR ProSAFE VPN Firewall FVS318G v2
Authentication Method Select Pre-shared key as the authentication method, and enter a key in the
Pre-shared key field.
Pre-shared key A key with a minimum length of 8 characters and no more than
49 characters. Do not use a double quote (''), single quote ('),
or space in the key.
Diffie-Hellman (DH)
Group
The DH Group sets the strength of the algorithm in bits. From the list, select Group
2 (1024 bit).
SA-Lifetime (sec) The period in seconds for which the IKE SA is valid. When the period times out, the
next rekeying occurs. The default setting is 28800 seconds (eight hours). However,
for a Mode Config configuration, NETGEAR recommends 3600 seconds
(one hour).
Enable Dead Peer
Detection
Note: See also
Configure Keep-Alives
and Dead Peer
Detection on
page 276.
Select whether Dead Peer Detection (DPD) is enabled:
Yes. This feature is enabled. When the VPN firewall detects an IKE connection
failure, it deletes the IPSec and IKE SA and forces a reestablishment of the
connection. You must specify the detection period in the Detection Period
field and the maximum number of times that the VPN firewall attempts to
reconnect in the Reconnect after failure count field.
No.
This feature is disabled. This is the default setting.
Detection Period The period in seconds between consecutive
DPD R-U-THERE messages, which are sent only when the
IPSec traffic is idle. The default setting is 10 seconds. This
example uses 30 seconds.
Reconnect after
failure count
The maximum number of DPD failures before the VPN firewall
tears down the connection and then attempts to reconnect to
the peer. The default setting is 3 failures.
Table 57. Add IKE Policy screen settings for a Mode Config configuration (continued)
Setting Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR FVS318G and is the answer not in the manual?

NETGEAR FVS318G Specifications

General IconGeneral
Power requirements12V DC, 1.5A
Firewall throughput250 Mbit/s
Maximum data transfer rate1000 Mbit/s
HTTP performance6000 transactions/sec
Wi-FiNo
DHCP serverYes
Number of VLANs256
VPN tunnels quantity12
WAN connectionEthernet (RJ-45)
Connectivity technologyWired
Ethernet LAN (RJ-45) ports9
Ethernet DMZ ports quantity1
Routing protocolsRIP-1, RIP-2
Supported network protocolsTCP/IP, UDP, ICMP, PPPoE
VPN supportIPsec (ESP), IKE, PKI, HTTPS
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, 3DES, DES, MD5, SHA-1
Internal memory128 MB
Flash memory32 MB
Storage media typeFlash
Processor frequency300 MHz
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 45 °C
Cables includedLAN (RJ-45)
Weight and Dimensions IconWeight and Dimensions
Weight590 g
Dimensions (WxDxH)190 x 125 x 35 mm