Net Mode Configuration Commands
72
ProSafe Gigabit Quad WAN SSL VPN Firewall SRX5308
Command example:
SRX5308>
net radvd configure lan
net-config[radvd-lan]>
enable Y
net-config[radvd-lan]>
mode Unsolicited-Multicast
net-config[radvd-lan]>
interval 60
net-config[radvd-lan]>
flags Managed
net-config[radvd-lan]>
preference Medium
net-config[radvd-lan]>
mtu 1496
net-config[radvd-lan]>
life_time 7200
net-config[radvd-lan]>
save
Related show command: show net radvd lan setup
net lan ipv6 prefix_delegation add
This command configures a new IPv6 prefix for LAN prefix delegation. To enable prefix
delegation for the IPv6 LAN, see the
net lan ipv6 configure command. After you have issued
the net lan ipv6 prefix_delegation add command, you enter the net-config
[lan-prefix-delegation] mode, and then you can configure the IPv6 prefix and IPv6 prefix
length in the order that you prefer.
interval seconds The interval in seconds (integer) between
unsolicited multicast RAs. Enter a period from 10
to 1800 seconds. The default is 30 seconds.
flags Managed or Other Specifies the flag:
• Managed. The DHCPv6 stateful protocol is
used for autoconfiguration of the address.
• Other. The DHCPv6 stateful protocol is used for
autoconfiguration of other (that is, nonaddress)
information.
preference Low, Medium, or High Specifies the VPN firewall’s preference in relation
to other hosts and routers in the LAN.
mtu number The MTU size (integer) that is used in the RAs to
ensure that all nodes in the network use the same
MTU size. The default is 1500 seconds.
life_time seconds The advertisement lifetime in seconds (integer) of
the route. The default is 3600 seconds.
Step 1 Format net lan ipv6 prefix_delegation add
Mode net
Keyword (might consist
of two separate words)
Associated Keyword to
Select or Parameter to Type
Description