Install the Internal HBA Card and HBA Super Capacitor
b.
Return the server to the normal rack position.
See “Return the Server to the Normal Rack Position” on page 220.
c.
Reconnect the power cords to the power supplies and power on the server.
See “Reconnect Power and Data Cables” on page 222 and “Power On the
Server” on page 222.
d.
Verify that the power supply AC OK LED is lit.
6.
Use Oracle ILOM to clear any server PCIe card faults.
If a PCIe card fault message in Oracle ILOM is not cleared under Open Problems, you must
manually clear the fault using Oracle ILOM. For instructions for manually clearing a PCIe
card fault, see the procedure "Clear Faults for Undetected Replaced or Repaired Hardware
Components" in the Oracle ILOM User's Guide for System Monitoring and Diagnostics in the
Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation Library at https://www.
oracle.com/goto/ilom/docs.
Related Information
■
“Remove the Internal HBA Card and HBA Super Capacitor” on page 182
188 Oracle Server X8-2L Service Manual • January 2021