Monitoring System Components
Disk Backplane Components
The following table lists the disk backplane (DBP) components.
Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)
/SYS/DBP FRU Disk backplane FRU
/SYS/DBP/PRSNT Discrete sensor Disk backplane presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0-x] Pseudo Hard disk drives (HDD)
/SYS/DBP/HDD[0-x]/PRSNT Discrete sensor Hard disk drive presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0-x]/STATE State sensor Hard disk drive state 01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
/SYS/DBP/HDD[0-x]/SERVICE Indicator Fault-Service Required
LED
Color: Amber
Location: HDD
Off: Normal
On: HDD was diagnosed as failed
/SYS/DBP/HDD[0-x]/OK2RM Indicator Hard disk drive OK to
remove
Color: Blue
Location: HDD
Off: Normal
On: HDD is OK to remove
/SYS/DBP/HDD[0-x]/NVME FRU NVMe drive FRU
/SYS/DBP/HDD[0-x]/NVME/PRSNT Discrete sensor NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
Related Information
“System Chassis Components” on page 291
“Cooling Unit Components” on page 293
“Memory Device Components” on page 295
“Power Unit Components” on page 295
294 Oracle Server X8-2L Service Manual • January 2021

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle X8-2L and is the answer not in the manual?

Oracle X8-2L Specifications

General IconGeneral
BrandOracle
ModelX8-2L
CategoryServer
LanguageEnglish

Related product manuals