Environmental Events
alert rule destinations to start receiving these traps, refer to the Oracle Integrated Lights Out
Manager (ILOM) 5.0 Documentation Library at https://www.oracle.com/goto/ilom/docs.
The tables in these sections list the set of SNMP traps that are generated from Oracle ILOM.
“Environmental Events” on page 301
“Hard Disk Drive Components” on page 299
“Power Events” on page 303
“Fan Events” on page 308
“Memory Events” on page 309
“Entity Presence Events” on page 310
Environmental Events
The following table lists environmental events.
Messages and Descriptions Component Name
SNMP Trap: sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A temperature sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
SNMP Trap: sunHwTrapTempCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A temperature sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
Monitoring Components and Identifying SNMP Messages 301