Disconnect Cables From the Server
When Main power is off, the System OK LED on the front panel begins blinking,
indicating that the server is in Standby power mode. See “Server System-Level Status
Indicators” on page 31.
2.
Disconnect the power cords and data cables from the server.
See “Disconnect Cables From the Server” on page 61.
Caution - When you power down the server using the On/Standby button, the server enters
Standby power mode. Power is still directed to the service processor and power supply fans. To
completely power off the server, you must disconnect the power cords from the power supplies.
Related Information
“Power Down the Server for Immediate Shutdown Using the Oracle ILOM
CLI” on page 59
“Power Down the Server for Immediate Shutdown Using the Oracle ILOM Web
Interface” on page 60
“Power On the Server” on page 222
Disconnect Cables From the Server
Caution - The system supplies Standby power to the circuit boards even when the system is
powered off.
1.
Label all cables connected to the server.
2.
Power down the server.
See “Powering Down the Server” on page 55.
3.
Disconnect the power cords from the rear of the server.
4.
Disconnect all data cables from the rear of the server.
5.
If your rackmount kit includes a cable management device, remove the cables
from it.
6.
Depending on the components that you are servicing, either extend the server to
the maintenance position, or remove the server from the rack.