Power Events
Messages and Descriptions Component Name
SNMP Trap: sunHwTrapSlotOrConnectorError
Oracle ILOM Event Message: Assert
Severity and Description: Major: A sensor associated with a slot or connector has detected an error.
/SYS/DBP/HDD[0-x]/STATE
SNMP Trap: sunHwTrapSlotOrConnectorOk
Oracle ILOM Event Message: Deassert
Severity and Description: Informational; A sensor associated with a slot or connector has returned
to its normal state.
/SYS/DBP/HDD[0-x]/STATE
Related Information
“System Chassis Components” on page 291
“Cooling Unit Components” on page 293
“Disk Backplane Components” on page 294
“Memory Device Components” on page 295
“Power Unit Components” on page 295
“Processor Components” on page 297
“System Motherboard Components” on page 297
“Hard Disk Drive Components” on page 299
Power Events
The following table lists power events.
Messages and Descriptions Component Name
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_PRESENCE ASSERT
Severity and Description: Major; A power supply sensor has detected an error.
/SYS/PS[0-1]/STATE
SNMP Trap: sunHwTrapPowerSupplyOk
Oracle ILOM Event Message: PS_PRESENCE DEASSERT
Severity and Description: Major; A power supply sensor has detected an error.
/SYS/PS[0-1]/STATE
SNMP Trap: sunHwTrapPowerSupplyError
Oracle ILOM Event Message: PS_FAILURE ASSERT
/SYS/PS[0-1]/STATE
Monitoring Components and Identifying SNMP Messages 303