Return the Server to the Normal Rack Position
Note - To pull the green release tab, place your finger in the center of the tab, not on the end,
and apply pressure as you pull the tab toward the front of the server.
b.
Continue pushing the server into the rack until the slide-rail locks (on the
front of the server) engage the slide-rail assemblies.
You will hear an audible click when the server is in the normal rack position.
2.
If the CMA is not installed, that is, you removed it because you removed the
server completely out of the rack, install the CMA.
For installation instructions for the CMA, refer to “Install the Cable Management Arm
(Optional)” in Oracle Servers X8-2 and X8-2L Installation Guide.
3.
If the cables are disconnected from the back of the server, that is, you
disconnected the cables because you extended the server out of the rack,
reconnect the cables.
■
For instructions to reconnect cables to the back of the server, see “Reconnect Power and
Data Cables” on page 222.
Returning the Server to Operation 221