Monitoring System Components
Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)
/SYS/PS[0-1] FRU Power supply FRU
/SYS/PS[0-1]/PRSNT Discrete sensor Power supply is
present.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/PS[0-1]/STATE Discrete sensor Multistate, power
supply sensor type, per
IPMI
Presence detected
Failure detected
Predictive failure
Power supply input lost
Power supply input lost or out-of-
range
Power supply input out-of-range
Configuration error
/SYS/PS[0-1]/P_IN Power sensor Input power draw Watts
/SYS/PS[0-1]/P_OUT Power sensor Output power Watts
/SYS/PS[0-1]/V_IN Voltage sensor Input voltage Volts
/SYS/PS[0-1]/V_12V Voltage sensor 12V output voltage Volts
/SYS/PS[0-1]/V_12V_STBY Voltage sensor 12V standby output
voltage
Volts
/SYS/PS[0-1]/T_IN Temperature sensor PSU input temperature Degrees Celsius
/SYS/PS[0-1]/T_OUT Temperature sensor PSU output
temperature
Degrees Celsius
Related Information
■
“System Chassis Components” on page 291
■
“Cooling Unit Components” on page 293
■
“Disk Backplane Components” on page 294
■
“Memory Device Components” on page 295
■
“Processor Components” on page 297
■
“System Motherboard Components” on page 297
■
“System Firmware Components” on page 299
■
“Hard Disk Drive Components” on page 299
296 Oracle Server X8-2L Service Manual • January 2021