Using the Configure Panel
Pipeline User’s Guide
43
74-0085-05
Timecode
Timecode Sources
(select one)
Select Auto, RS422, SDI, Channel 1 (Pipeline Quad only) or SNTP. In
Auto mode, Pipeline selects the time code source by priority (Pipeline SC
– auto mode clock source options and Pipeline Quad and HD Dual– auto
mode clock source options on page 105).
For Pipeline Quad channels 2, 3, and 4, you can select Channel 1 as the
source. Channel 1 itself must be set to an external source.
Note: Auto selection is ignored by the Pipeline Control application, whose
schedule settings override those of the selected Pipeline.
SNTP Server When SNTP is selected as a time code source, edit field for entry of
SNTP server IP address.
Buttons If another user is connected and processing media with this Pipeline,
using these buttons will interrupt the process, and it must be re-started.
Save Changes Click to update the Pipeline with the new settings. If you change the IP
address (by any means – returning to self-assigned, enabling DHCP, or
assigning a static address), in about 30 seconds, Pipeline Direct displays
an error: “Unable to communicate with Pipeline”. Click OK, then
reconnect to the Pipeline using the new IP address.
Default Return settings to default.
Reboot This reboot performs a hardware-level reset, which disconnects Pipeline
from any client which may attached without warning. Click to reboot the
Pipeline if you change the password, to log on using the new password.
You do not need to reboot when changing IP settings.
Soft Reboot This reboot resets the Pipeline without disconnecting from an attached
client. In cases where the Pipeline is non-responsive, click Software
Reboot to clear the problem and continue. However, performing a soft
reboot during streaming will interrupt the stream.
Control Description