Cylinder Head and Valves
02
020
7
RG,RG34710,63 –19–16OCT00–4/6
8. Set electronic unit injector preload by turning the EUI
rocker arm adjusting screw in until there is zero
clearance between the rocker arm roller and camshaft
lobe. Next, turn the adjusting screw in an additional
one-half turn (180°). Hold adjusting screw stationary
while tightening lock nut to specified torque. Tighten
EUI adjusting screw lock nuts to specifications.
Specification
Electronic Unit Injector—Preload 0.00 mm (in.) clearance plus 1/2
turn in (180°)
...........
Electronic Unit Injector Adjusting
Screw Lock Nuts—Torque 65 N•m (48 lb-ft)..............................................
Continued on next page
CTM100 (06APR04)
02-020-7
P
OWER
T
ECH
10.5 L & 12.5 L Diesel Engines
040604
PN=79