MANUAL NUMBER 160339
REVISION 09SEPT04 PAGE 16
EVERY 18000 MILES OR SEMI-ANNUALLY (whichever occurs first)
Perform a comprehensive fire system test using a Kidde Dual Spectrum System Test Set
(Optical Test Kit P/N 420871-2)
EVERY SIX YEARS
Have the fire extinguisher rebuilt by a qualified fire protection equipment company familiar
with Kidde Dual Spectrum equipment. Rebuild shall include squib, valve seals and dry
chemical replacement.
At time of rebuild, if 12 or more years have passed since last hydrostatic test of the fire
extinguisher cylinder; have the cylinder hydrostatically tested by a qualified fire protection
equipment company familiar with Kidde Dual Spectrum equipment.