Alteon Application Switch Operating System Application Guide
ADC-VX Management
Document ID: RDWR-ALOS-V2900_AG1302 445
3. At the prompt, select the image ID for the new infrastructure image.
Loading vADC Images
ADC application images are used by vADCs and standalone ADCs. Assigning an application image
does not interfere with neighboring vADCs or vADCs currently running with the same image version.
Application images are reusable and can be assigned in bulk, one by one, or for the entire system.
Upgrading a Single vADC
vADCs can use any of the 10 ADC application images loaded on the system.
To upgrade a single vADC
1. Access the Active Switch Configuration Boot menu.
2. Enter image, and select the image type used for the upgrade.
>> Global - Boot Options# gtimg
Enter image type [all|vx|adc]: vx
ADC-VX Infrastructure Images:
ID Version Downloaded Image status
-- ------- ---------- ------------
1 28.1.0.3 17:41:28 Sun Jan 13, 2013 Idle
2 28.1.0.0 12:45:39 Wed Mar 31, 2013 Active
3 28.1.0.1 17:41:28 Sun Jan 13, 2013 Idle
4 28.1.0.2 12:45:39 Wed Mar 31, 2013 Idle
Enter image ID: (1-4) 1
Enter hostname or IP address of FTP/TFTP/SCP server: 10.210.31.39
Enter name of file on FTP/TFTP/SCP server: AAS-28.1.0.12--IF-AlteonOS
Enter username for FTP/SCP server or hit return for TFTP server: