Alteon Application Switch Operating System Application Guide
ADC-VX Management
Document ID: RDWR-ALOS-V2900_AG1302 447
Upgrading a Group of vADCs
You can upgrade a group of vADCs by entering their ID numbers separated by a comma, or entering
a range of vADCs. For example, enter 1-10, 25 to upgrade vADCs 1 to 10 and vADC 25. After
upgrading, restart all relevant vADCs for the changes to apply.
To upgrade a group of vADCs
1. Access the Active Switch Configuration Boot menu.
2. Enter image, and select the image type used for the upgrade.
3. Restart the vADC processes.
>> Global - Boot Options# image
Enter image type [vx|adc]: adc
ADC Application Images:
ID Version Downloaded Image status vADC IDs
-- ------- ---------- ------------ --------
1 17:41:28 Sun Jan 13, 2013 Incompatible -
2 28.1.0.0 12:45:39 Wed Mar 31, 2013 Active 6
3 28.1.0.2 17:41:28 Sun Jan 13, 2013 Active 7
4 28.1.0.3 12:45:39 Wed Mar 31, 2013 Active 10-12
5 28.1.0.4 17:41:28 Sun Jan 13, 2013 Active 15-20
6 28.1.0.5 12:45:39 Wed Mar 31, 2013 Idle 28
7 28.1.0.6 17:41:28 Sun Jan 13, 2013 Idle 1-5
8 - - - -
9 28.3.0.0 17:41:28 Sun Jan 13, 2013 Active 22
10 28.4.0.0 12:45:39 Wed Mar 31, 2013 Idle -
Enter vADC ID: (1-28) 1,4 10-15
Enter image ID: (1-10) 10
Image 10 instead of image 7 will be used by vADC 1,4,10-15 next vADC restart
>> Global - Boot Options# /boot/vadc
Enter vADC Number [1-28]: 1,4 10-15
WARNING: There are unapplied/unsaved configuration changes.
Confirm Operation without apply/save changes [y/n]: y
vADCs 1-5, 28 set to restart. Are you sure? [y/n]: y