Resetting Chapter 8
WinLink™ 1000 User Manual Release 1.9 8-19
2. Choose an alarm and set its mode to Enabled or Disabled
3. Enter a description of the alarms in the text field.
4. Click Apply to save.
5. Click OK to exit from the dialog.
Resetting
You may reset the link, preserving the current configuration, or reset to fac-
tory defaults.
¾ To reset the link preserving current configuration:
1. From Maintenance on the main window, reset the remote unit.
2. From Maintenance on the main window, reset the local unit.
¾ To reset to Factory Defaults
1. Choose either of the sites to be reset. The Configuration dialog box
opens.
2. Choose Operations in the Configuration dialog box.
Figure 8-18: Site Configuration - Reset to factory defaults
3. Click the Restore Defaults button.
A message box asking if you want to restore factory default settings
appears.
Caution
Resetting the link causes service disconnection.
To maintain the connection between the managing computer and
the link, first reset Site B.