RADWIN Manager Traps Appendix Q
WinLink™ 1000 User Manual Release 1.9 Q-22
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events.
These traps are shown in the RADWIN Managerr Events Log.
A list of Trap Messages as displayed by the RADWIN Manager is shown in
Table 9-5.
mngPortClear 211 normal Indicates the management port status changed to connected.Contains
two parameters:1 - Description: Management port status changed to
connected - %s2 - %s Is the Eth. mode (speed & duplex)
externalAlarmInPort3Clear 212 normal This Trap is sent every time an External Alarm Input fault of port # 3 is
cleared.Contains a single parameter, which is its description:1 -
Description: External Alarm 3 - <User Text> - Alarm Cleared.
externalAlarmInPort4Clear 213 normal This Trap is sent every time an External Alarm Input fault of port # 4 is
cleared.Contains a single parameter, which is its description:1 -
Description: External Alarm 4 - <User Text> - Alarm Cleared.
swVersionsMatchFullCompatibilityClear 214 normal The trap is sent if SW versions match.Contains a single parameter,
which is its description:1 - Description: Software Versions compatible
swVersionsMatchRestrictedCompatibilityClear 215 normal The trap is sent if SW versions match and link functionality is not
restricted.Contains a single parameter, which is its description:1 -
Description: Software Versions compatible
swVersionsMatchSoftwareUpgradeRequiredClear 216 normal The trap is sent if SW versions match and SW upgrade is
successful.Contains a single parameter, which is its description:1 -
Description: Software Versions compatible
swVersionsCompatibleClear 217 normal The trap is sent if SW versions compatibleContains a single parameter,
which is its description:1 - Description: Software Versions compatible
hssMultipleSourcesDisappearedClear 218 normal Indicates that multiple sync pulse sources disappeared.Contains a single
parameter, which is its description:1 - Description: HSS multiple sync
pulse sources disappeared.
hssSyncToProperSourceAchievedClear 219 normal Indicates that synchronization to a proper Sync source was
achieved.Contains a single parameter, which is its description:1 -
Description: HSS sync pulse - Up.
hssSyncPulseDisappearedClear 220 normal Indicates that HSS additional sync pulse disappeared.Contains a single
parameter, which is its description:1 - Description: HSS additional sync
pulse was disappeared.
tdmBackupClear 221 normal Indicates that the TDM main link was activated.Contains a single
parameter, which is its description:1 - Description: TDM main link was
activated.
linkLockAuthorizedRemoteODU 222 normal Indicates that the remote ODU is authorized.Contains a single
parameter, which is its description:1 - Description: Authorized remote
ODU connection accepted.
linkLockAuthorizedODU 223 normal Indicates that the ODU is authorized.Contains a single parameter, which
is its description:1 - Description: Authorized ODU connection permitted.
linkAuthenticationDisabled 224 normal Indicates that the Link Lock is disabled.Contains a single parameter,
which is its description:1 - Description: Link Authentication has been
disabled.
hotStandbyClear 225 normal Indicates that the Primary Link Was Activated.Contains a single
parameter, which is its description:1 - Description: Primary Link Is Active.
sfpExtraction 226 normal Indicates that a device was extracted from SFP Port
sfpPort1Clear 227 normal Indicates the SFP port 1 status changed to connected.Contains two
parameters:1 - Description: SFP port 1 status changed to connected -
%s2 - %s Is the Eth. mode (speed & duplex)
compatibleIdus 228 normal Indicates that the ODU has identified compatible Idus on both sides of the
link.
Table Q-3: MIB Traps (Sheet 4 of 4)
Name ID Severity Description