The RADWIN Manager log-on Concept Chapter 4
WinLink™ 1000 User Manual Release 1.9 4-5
Figure 4-5: Log on window exposing the user types.
There are three user types:
•An
Observer
has read-only access to the link. An Observer can
monitor the link, generate reports, but may not change any link
parameters.
•An
Operator
can install and configure the link.
•An
Installer
can, in addition to functioning as an Operator, also
change the operating band. The latter function has legal ramifica-
tions, requiring familiarity with local regulations.
The following table summarizes these options:
The Network Manager should change the default passwords as soon as pos-
sible.
¾ Continuing the log-on procedure:
5. Type an IP address for the ODU (if you connect through a LAN), or click
Local Connection (if you are connected directly to the IDU port).
Table 4-2: User types, default passwords and function
User Type
Default
Password
Function Community
Community
String
Observer
admin
Monitoring Read-Only
public
Operator
admin
Installation,
configuration
Read-Write
netman
Installer
wireless
Operator plus
set band
Read-Write
netman

Table of Contents