WinLink™ 1000 User Manual Release 1.9 D-1
Appendix D
Preloading an ODU with
an IP Address
Why this is Needed?
All ODUs supplied by RADWIN come pre-configured with an IP address of
10.0.0.120. For use in a network, the ODUs must be configured with suit-
able static IP addresses. The method for doing this under office conditions
is set out in Chapter 5.
This appendix explains how do achieve the same thing in the field.
Required Equipment
The minimal equipment required to pre-load an ODU with an IP address is:
• Laptop computer (managing computer) satisfying the requirements
of Table 4-1
• An installed copy of the RADWIN Manager
• A PoE device
• A crossed Ethernet LAN cable
• An IDU-ODU cable
• If you have connectorized ODUs, two N-type RF terminators
The procedure
¾
To Preolad an ODU with an IP address:
1. Using the IDU-ODU cable, connect the PoE device to the ODU, ensuring
that the cable is plugged into the PoE port marked P-LAN-OUT.
Note
The following procedure is generic to all RADWIN radio products. What you
see on your running RADWIN Manager may differ in some details from the
screen captures used to illustrate this Appendix.