The procedure Appendix D
WinLink™ 1000 User Manual Release 1.9 D-5
12. Click Yes to accept the change. After about half a minute the changes
will be registered in the ODU. On the left hand panel of the main win-
dow, you will see the new IP configuration for the ODU.
Figure D-7: Main Window after IP Address change
13. Click Cancel to leave the open Management dialog. You may now exit
the RADWIN Manager, or connect to another ODU. If you choose to con-
nect to another ODU, after about a minute, the main window of the RAD-
WIN Managerwill revert to that shown in Figure D-2 above. In any
event, power down the changed ODU; the IP address change will take
effect when you power it up again.
Note
Don’t forget to remove the RF terminators from a connectorized ODU after
powering it down.