ODU/HSS Unit Connection Pinout Appendix H
WinLink™ 1000 User Manual Release 1.9 H-4
4. Tighten the protective seal that is on the prepared cable over the RJ-45
connector.
5. Repeat for all ODUs that are to be collocated at the hub site. The next
ODU to be connected is inserted to SYNC 2, followed by SYNC 3 and so
on.
ODU/HSS Unit Connection Pinout
Radio Frame Pattern Table
Under HSS, the TDD mechanism of the collocated radios transmits at the
same time and receives at the same time. The cycle duration of transmit
and receive is called
Radio Frame Pattern
(RFP) and with RADWIN 2000 it is
always 1250 milliseconds.
Note
In the event of an HSS installation fault, the ODU will sound a beep pattern
according to the following chart, which may also be seen on the ODU
product label:
Table H-1: ODU/HSS Unit Connection Pinout
Color ODU RJ-45
HSS UNIT
RJ-45
White/Green 1 1
Green 2 2
White/Orange 3 3
Orange 6 6
Blue 4 4
White/Blue 5 5
White/Brown 7 7
Brown 8 8