Setting the Date and Time Chapter 8
WinLink™ 1000 User Manual Release 1.9 8-12
The Link Lock check-box is now unavailable.
5. If required, repeat the procedure for Site B.
Setting the Date and Time
The ODU maintains a date and time. The date and time should be synchro-
nized with any Network Time Protocol (NTP) version 3 compatible server.
During power-up the ODU attempts to configure the initial date and time
using an NTP Server. If the server IP address is not configured or is not
reachable, a default time is set.
When configuring the NTP Server IP address, you should also configure the
offset from the Universal Coordinated Time (UTC). If there is no server
available, you can either set the date and time, or you can set it to use the
date and time from the managing computer. Note that manual setting is not
recommended since it will be overridden by a reset, power up, or synchroni-
zation with an NTP Server.
Note
To revert the Link Lock status to unlocked, power down each ODU
in turn. Use the above procedure to uncheck the Link Lock status
box for the live ODU.
A simple ODU reset at either end will restore the link to its previous
locked or unlocked state.
Note
The NTP uses UDP port 123. If a firewall is configured between the ODU
and the NTP Server this port must be opened.
It can take up to 8 minutes for the NTP to synchronize the ODU date and
time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin WinLink 1000 Series and is the answer not in the manual?

Radwin WinLink 1000 Series Specifications

General IconGeneral
BrandRadwin
ModelWinLink 1000 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals