Events, Alarms and Traps Chapter 9
WinLink™ 1000 User Manual Release 1.9 9-13
Ethernet service, there is throughput degradation in case of interference.
The degradation is proportional to the BBER.
Ethernet Thresholds - Capacity
This is used as a basis for checking adherence to a Service Level Agree-
ment. It is the number of seconds count that the link capacity falls bellow
the threshold.
Ethernet Thresholds - Traffic
The number of seconds count that received traffic exceeded this threshold.
It can be used to measure traffic peaks.
Events, Alarms and Traps
The Events Log
The Events Log records system failures, loss of synchronization, loss of sig-
nal, compatibility problems and other fault conditions and events.
Alarms (traps) are displayed in the Events Log in the lower panel of the
main window. The Events Log may be saved as a text file.
The Events Log includes the following fields:
» Sequential number (ID)
» Date and time stamp
» Message
» Trap source
» IP address of the ODU that initiated alarm.
For complete information about traps and alarms see Appendix M,
Table M-3.
The events are displayed in the Events Log in the lower right-hand panel of
the RADWIN Manager main window:
Note
The foregoing event types include events from all links for which this
managing computer has been defined as the traps address. Only events
from RADWIN equipment will be shown.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin WinLink 1000 Series and is the answer not in the manual?

Radwin WinLink 1000 Series Specifications

General IconGeneral
BrandRadwin
ModelWinLink 1000 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals