Configuration with Telnet Chapter 8
WinLink™ 1000 User Manual Release 1.9 8-23
Figure 8-21, below, shows the available Telnet commands using the help
command.
set trappw <oldpasswd> <passwd> Set the trap Community string
set buzzer <mode:0=OFF,1 =ON> Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between minimal
Tx power, and maximal Tx power>
Set the ODU Tx Power. If a wrong value is entered, both
min and max values shall be displayed in the error reply
set bridge <mode:0=Bridging OFF,1=
Bridging ON >
Set the ODU bridge mode (0 – off, 1 – on)
set name <new name> Set the name of the link
set location <new location> Set the name of the location
Set contact <new contact> Set the name of the site manager
set Ethernet <>port:MNG,LAN1,LAN2>
<mode:AUTO,10H,10F,100H,100F,DIS
ABLE>
Set the mode and speed of each Ethernet port
reboot Resets both the IDU and the ODU. The user is warned that
the command will reset the ODU. A new Telnet session to
the ODU may be opened after the reset is complete.
(Watch the IDU LEDs.)
help Displays the available commands
Table 8-2: Telnet Commands (Continued)
Command Explanation