Running the Link Budget Calculator Appendix B
WinLink™ 1000 User Manual Release 1.9 B-13
7. Click Calculate to obtain the required performance estimate.
The Expected Performance parameters are calculated and displayed:
Expected RSS - the expected RSS that the RADWIN Manager
shows when the WinLink™ 1000 ODUs are optimally aligned
Services Type - max number of T1 or E1 trunks if “Max Trunks” is
selected
Ethernet Rate - maximum throughput available for the chosen
parameter combination
Antenna height for LOS – the minimum antenna height required
for line-of-sight operation. It is the sum of the height required for
boresight clearance due to the earth’s curvature plus the height
required to clear the Fresnel zone
If the expected performance is not suitable for your application, try different
parameters and repeat the calculation.
Note
Placing the cursor in any other calculated field will also update the
calculated results.