MIB Parameters Appendix Q
WinLink™ 1000 User Manual Release 1.9 Q-13
winlink1000OduPerfMonEthDayIdx RO This table is indexed per Day number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonEthDayRxMByte
s
RO Current RX Mega Bytes per day.
winlink1000OduPerfMonEthDayTxMByte
s
RO Current Transmit Mega Bytes per day.
winlink1000OduPerfMonEthDayEthCapa
cityThreshUnder
RO The number of times throughput was below
threshold each day.
winlink1000OduPerfMonEthDayHighTraff
icThreshExceed
RO The number of times actual traffic was above
threshold each day.
winlink1000OduPerfMonTdmCurrTable N/A This table defines/keeps the TDM counters of the
current 15 min interval.
winlink1000OduPerfMonTdmCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonTdmCurrActiveS
econds
RO Parameter indicating whether the TDM service
was active. Under TDM backup link
winlink1000OduPerfMonTdmIntervalTabl
e
N/A This table defines/keeps the TDM counters of the
last day (in resolution of 15 min intervals).
winlink1000OduPerfMonTdmIntervalEntr
y
N/A This is an entry in the Interval Table. INDEX
{ifIndex
winlink1000OduPerfMonTdmIntervalIdx RO This table is indexed per interval number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmIntervalActiv
eSeconds
RO Parameter indicating whether the TDM service
was active.Under TDM backup link
winlink1000OduPerfMonTdmDayTable N/A This table defines/keeps the TDM counters of the
last month (in resolution of days).
winlink1000OduPerfMonTdmDayEntry N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonTdmDayIdx RO This table is indexed per Day number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmDayActiveS
econds
RO Parameter indicating whether the TDM service
was active.Under TDM backup link
winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.20 Integer RW When the Transmit power exceeds this threshold
winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.21 Integer RW When the RX power exceeds this threshold
winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.22 Integer RW When the RX power exceeds this threshold
winlink1000OduPerfMonBBERThresh1 1.3.6.1.4.1.4458.1000.1.6.23 Integer RW When the BBER exceeds this threshold
winlink1000OduPerfMonEthCapacityThre
shKbps
RW When the current throughput is below this
threshold
winlink1000OduPerfMonHighTrafficThres
hKbps
RW When the current traffic is above this threshold
winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1.1 Integer RW If 'yes' is chosen
winlink1000OduAgnGenSetMode 1.3.6.1.4.1.4458.1000.1.7.1.2 Integer RW This parameter is reserved to the element
manager provided with the product.
winlink1000OduAgnNTPCfgTimeServerI
P
1.3.6.1.4.1.4458.1000.1.7.2.1 IpAddress RW IP address of the server from which the current
time is loaded.
winlink1000OduAgnNTPCfgTimeOffsetFr
omUTC
1.3.6.1.4.1.4458.1000.1.7.2.2 Integer RW Offset from Coordinated Universal Time (minutes).
Possible values: -1440..1440.
Table Q-2: Private MIB Parameters (Sheet 9 of 14)