EasyManua.ls Logo

Radwin WinLink 1000 Series - Page 74

Radwin WinLink 1000 Series
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Chapter 5
WinLink™ 1000 User Manual Release 1.9 5-4
Figure 5-2: Installation Wizard, System dialog box
¾ To complete Installation Step 2:
1. Enter a Link ID. The Link ID must be identical for both ODUs in the
link, otherwise they will not communicate. The Link ID must
include at least eight alphanumeric characters. Up to 24 characters are
allowed. You should use a Link ID composed of both alphabetic and
numeric characters.
2. Enter a Link Name for the link identification. The default name is “Link”.
You should change it.
3. Enter names for Site 1 and Site 2. The default names are both “Location”.
You should change them. Throughout this manual, we use A for Site 1
and B for Site 2.
4. Optionally enter a new Link Password.
5. Click Next.
The default link with a rate of 6.5 Mbps is evaluated.
Note
If the Link Password is incorrect a link is established but configuration
cannot be performed and no services are available. A new link password
may be obtained from RADWIN Customer Support or use the alternative
password supplied with the product.
The link password is peculiar to the link itself and should not be confused
with the RADWIN Manager log on password.

Table of Contents