Installation Chapter 5
WinLink™ 1000 User Manual Release 1.9 5-16
3. Click the required parameter. Their meanings are as follows:
Transparent/Transparent
The clock at Site A regenerates the clock from Site B and
vice versa.
Loop time/Recover
The Site A port receive-clock is used as the transmit-clock
for that port on both sides of the link.
Recover/Loop time
The Site B port receive-clock is used as the transmit-clock
for that port on both sides of the link.
Internal/Recover
The Site A port uses its internal oscillator to generate its
transmit clock while the Site B port regenerates the clock
received at the Site A port.
Recover/Internal
The Site B port uses its internal oscillator to generate its
transmit clock while the Site A port regenerates the clock
received at the Site B port.
4. Click Finish to complete the wizard.
Note
Please keep in mind that what follows is
per port
.