Elements of the RADWIN Manager Main Window Chapter 6
WinLink™ 1000 User Manual Release 1.9 6-7
• Immediately below the title bar is displayed the Estimated Time
Between Errors. It is zeroed by the Clear Counters button in
the tool bar.
• For each Trunk the line status and Error block count is dis-
played. It is zeroed by the Clear Counters button in the tool
bar. The line status is color coded and may be one of:
•Green - Normal
• Red - Error: LOS for loss of signal and AIS for Alarm Indi-
cation Signal
• Yellow - loopback
• Frequency box: It shows the link frequency. The color of the box
indicates the status
• Green is an active link
• Red is an inactive link
• Magenta shows an authentication or compatibility problem
• Brown shows severe compatibility problem
Events Log
The Events Log, stores alarms generated from both sides of the link and is
detailed in Chapter 9.
Status Bar
The Status bar, displays the following icons: