Remote Control
R&S
®
FSPN
328User Manual 1179.4363.02 ─ 01
Suffix:
<n>
.
irrelevant
<j> irrelevant
<t> irrelevant
Return values:
<values> <numeric value>
Default unit: dB
Example: //Query DUT gain
FETC:RANG:PNO:DUT:GAIN?
would return, e.g.
2.28
Usage: Query only
FETCh<n>:PNOise<t>:SPURs?
This command queries the location and level of all spurs that have been detected.
Suffix:
<n>
.
Window
<t> Trace
Return values:
<SpurCoordinates> Returns two values (frequency and level) for each each spur that
has been detected.
Example: //Query spur characteristics
FETC:PNO:SPUR?
would return, e.g.
1999.232666,-0.639974,6494.312500,-0.760579,
19992.324219,-0.639974
Usage: Query only
Manual operation: See "Spurious List" on page 90
FETCh<n>:PNOise<t>:SPURs:COUNt?
This command queries the number of spurious included in the spurious list.
Suffix:
<n>
.
1..n
Window
<t> 1..n
Trace
Return values:
<Count> Number of spurious
Example:
FETCh:PNO:SPURs:COUNt?