EasyManua.ls Logo

R&S FSPN - Fetch<N>[:Range<J>]:Pnoise<T>:Ipn; Fetch<N>[:Range<J>]:Pnoise<T>:Ram

R&S FSPN
555 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
FSPN
330User Manual 1179.4363.02 ─ 01
<t> Trace
Return values:
<arg0> <numeric value>
Default unit: s
Example: //Query random jitter
FETC:PNO:SPUR:RAND?
would return, e.g.
3.59e-09
Usage: Query only
Manual operation: See "Spurious List" on page 90
FETCh<n>[:RANGe<j>]:PNOise<t>:IPN?
This command queries the integrated phase noise.
Suffix:
<n>
.
Window
<j> Integration range
<t> Trace
Return values:
<Level> <numeric value>
Default unit: dBc
Example: //Query integrated phase noise
FETC:RANG2:PNO2:IPN?
would return, e.g.
-16.79
Usage: Query only
Manual operation: See "Integrated Measurements" on page 89
FETCh<n>[:RANGe<j>]:PNOise<t>:RAM?
This command queries the residual AM.
Suffix:
<n>
.
Window
<j> Integration range
<t> Trace
Return values:
<Am> <numeric value>
Default unit: PCT
Measurements and Result Displays

Table of Contents

Related product manuals