Remote Control
R&S
®
FSPN
438User Manual 1179.4363.02 ─ 01
11.7.5 Limit Lines
● Managing Limit Lines............................................................................................ 438
● Designing Limit Lines............................................................................................442
● Reading out the Results of a Limit Check.............................................................448
● Programming Example: Using Limit Lines............................................................ 449
11.7.5.1 Managing Limit Lines
CALCulate<n>:LIMit<li>:ACTive?.....................................................................................438
CALCulate<n>:LIMit<k>:COMPatible?..............................................................................438
CALCulate<n>:LIMit<li>:COPY........................................................................................439
CALCulate<n>:LIMit<li>:DELete...................................................................................... 439
CALCulate<n>:LIMit<li>:LOWer:OFFSet...........................................................................439
CALCulate<n>:LIMit<li>:LOWer:STATe.............................................................................440
CALCulate<n>:LIMit<li>:STATe........................................................................................440
CALCulate<n>:LIMit<li>:TRACe<t>..................................................................................441
CALCulate<n>:LIMit<li>:TRACe<t>:CHECk......................................................................441
CALCulate<n>:LIMit<li>:UPPer:STATe............................................................................. 442
CALCulate<n>:LIMit<li>:ACTive?
This command queries the names of all active limit lines.
Suffix:
<n>
.
irrelevant
<li> irrelevant
Return values:
<LimitLines> String containing the names of all active limit lines in alphabeti-
cal order.
Example:
CALC:LIM:ACT?
Queries the names of all active limit lines.
Usage: Query only
Manual operation: See " Visibility " on page 178
CALCulate<n>:LIMit<k>:COMPatible?
This command queries if the currently selected limit line is compatible to the current
measurement configuration.
Suffix:
<n>
.
1..n
irrelevant
Common Analysis and Display Functions