Remote Control
R&S
®
FSPN
437User Manual 1179.4363.02 ─ 01
CALCulate<n>:DELTamarker<m>:X:RELative?................................................................. 437
CALCulate<n>:DELTamarker<m>:Y?............................................................................... 437
CALCulate<n>:MARKer<m>:Y?.......................................................................................437
CALCulate<n>:DELTamarker<m>:X:RELative?
This command queries the relative position of a delta marker on the x-axis.
If necessary, the command activates the delta marker first.
Suffix:
<n>
.
Window
<m> Marker
Return values:
<Position> Position of the delta marker in relation to the reference marker.
Example:
CALC:DELT3:X:REL?
Outputs the frequency of delta marker 3 relative to marker 1 or
relative to the reference position.
Usage: Query only
CALCulate<n>:DELTamarker<m>:Y?
Queries the result at the position of the specified delta marker.
Suffix:
<n>
.
1..n
<m> 1..n
Return values:
<Result> Result at the position of the delta marker.
The unit is variable and depends on the one you have currently
set.
Default unit: DBM
Usage: Query only
CALCulate<n>:MARKer<m>:Y?
Queries the result at the position of the specified marker.
Suffix:
<n>
.
1..n
<m> 1..n
Return values:
<Result> Default unit: DBM
Usage: Query only
Common Analysis and Display Functions