ECODRIVE03 Drive Controllers ECODRIVE03 Auxiliary Bleeder Module BZM01.3 6-3
Ambient and operating conditions
See page 4-4: "Ambient and operating conditions"
Electrical data of auxiliary component BZM01.3
Power section
3.10MZBtinUlobmySnoitangiseD
esahp eerhtesahp elgnissniam eht ta edom gnitarepO
The connection is for protection purposes.
See page 6-14: "ZKS control input" and
page 11-5: "Control Circuits with internal DC bus
dynamic brake (ZKS)"
Nominal charging current
(dependent on mains input voltage)
I
EIN1
0 ~A
Uegatlov tupni sniaM
N1
V
fycneuqerf sniaM
N1
Hz
See page 4-6: "Mains connections, Power
section"
esiwkcolc-retnuoc ro esiwkcolcdleif yratoR
Device power dissipation without
internal continuous bleeder power
P
V
21W
Peak bleeder power BZM P
BS,BZM
021Wk
Continuous bleeder power BZM
when Ta<45 °C
under max. temperature range
at a distance
P
BD,BZM
d
kW
K
mm
1
110
80
max. available continuous bleeder
power in the DC bus if operating:
1 x DKC**.3-040-7
1 x DKC**.3-100-7
1 x DKC**.3-200-7
frotcaf yrtemmys htiw
kW
kW
kW
0.92
1.2
1.6
0.8
Max. energy Max. energy dissipation
BZM
W
R,MAX,BZM
001sWk
Internal DC bus dynamic brake
(ZKS)
contained
nominal DC bus capacitance BZM C
ZW
33.0Fm
Allowed input voltage at L+, L- at X5 U
ZW
V DC bus voltage ECODRIVE
DC (300 ... 800)
Cooling power section and bleeder
resistor
with internal blowers
Volumetric capacity of the forced
cooling
m³ 84 .xorppah/
Insulation resistance at DC500V R
is
51 >mhOM
Fig. 6-3: Technical data mains connection and power section