ECODRIVE03 Drive Controllers ECODRIVE03 DKC**.040, DKC**.100, DKC**.200 4-31
Allowed DC bus continuous power with CZM01.3 auxiliary components
Note: The allowed DC bus continuous power of the drive controllers
is increased by adding components.
• CZM01.3 reduces the load of the DC bus capacitor in drive controllers.
DKC**.3-040-7 with CZM01.3 in "Single source supply":
No increase in the allowed continuous power!
DKC**.3-040-7 with CZM01.3 in "Group supply without
DC bus connection":
No increase in the allowed continuous power!
See page 4-23: "Arranging the Group supply without DC bus connection"
DKC**.3-040-7 with CZM01.3 in "Group supply with DC
bus connection":
No increase in the allowed continuous power!
DKC**.3-040-7 with CZM01.3 in "Central supply":
DKC**.3-040-7 as supply in „central supply “ not allowed!
Note: Denition of terms, see page 4-19: "Mains supply options".