ECODRIVE03 Drive Controllers ECODRIVE03 Auxiliary Bleeder Module BZM01.3 6-5
CE Label, Tests
CEf1.fh7
Fig. 6-6: CE marking
High-voltage test according to
EN50178
Routine test with DC2100V 1 s
Insulation test according to EN50178 Routine test with DC500V 1 s
Separation between the electrical
circuits of the control and high
voltage power
safe separation according to
EN50178
Clearances and creepage distances according to EN50178
Fig. 6-7: Tests
CE label:
Tests: