16-6 srellortnoC evirD 30EVIRDOCEtnemhcattA
16.2 Use of the connections for looping through the control
voltage
Ap5404f1.fh7
24V
123 4
567 8
X1
123 4
567 8
X1
123 4
567 8
X1
Fig. 16-11: Looping through the control voltage
Calculation for 3 DKC02.3-040 drive controllers:
I
D
= 3 x
3
3
N
N
U
P
= 3 x
V
W
24
19
= 2,31 A
Fig. 16-12: Continuous current I
D
I
E
= 3 x I
EIN3
= 3 x 4 A= 12 A
Fig. 16-13: Charging current I
E
Duration of the charging current peak according to gure Amplitude of the
DKC control voltage charging current at startup, to selecting power
source" on page 4-15: approx. 12 ms
Note: In the case of the DKC**.3-016-7-FW, the control voltage