ECODRIVE03 Drive Controllers ECODRIVE03 DKC**.040, DKC**.100, DKC**.200 4-21
Selection criteria for supply options
Mains supply options
Selection criteria for
"Mains supply
options."
Single
source
supply
Group supply
without DC bus
connection
Group supply
with DC bus
connection
Central supply
only 40 A units
X X X
only 100 A units
XXX
only 200 A units
XXX
Units with dierent current
types
XXX
(via unit with
highest current
type )
largest possible continuous
bleeder output
X X
largest possible peak
bleeder output
X X
largest possible
regenerative power
X X
largest possible DC bus
output
X
X
1)
least possible installation
resources (space, wiring,
fuse protection)
X
highest level of availability
of the drive package in case
of error
X
smallest possible charging
current inrush
X
fastest possible DC bus
charging
X
2)
X
3)
Fig. 4-21: Selection criteria for supply options
1) Limited to the specications of the used tripping circuit breaker.
2) No power ux of high power drives onto those with low power ux.
3) All participating discharge units (self or ZKS-discharging) operate
parallel.