tnemhcattAsrellortnoC evirD 30EVIRDOCE 16-29
16.7 Signal Sequence DKC**.3
Recommended Switching On Sequence
t
SV5076f1.fh7
t1
t2
t3
t4
t5
t6
t7
t8
internal signal
Command values
will take eect
AH is present at
the start signal
DKC**.3 signal sequence with recommended
startup sequence
AH takes eect
internally / for
asynchronous motors
Brake contact
actuated
Control voltage
applied
Bb contact closed
Mains voltage applied
Ud message
RF applied
Motor brake
released
AH takes eect
internally / for
synchronous motors
Fig. 16-38: Recommended switching on sequence
t1: Depends on functions and conguration.
t2: Made up of "Slow operation of mains contactor K1" and "PLC times".
t3: See page 4-55: "Digital outputs (ready, warning and UD-message)".
t4: Apply RF after signal U
D
-Signal.
t5: Internal delay time 8 ms.
t6: 300 ms due to eld built up in asynchronous motors, not applicable
to synchronous motors.
t7: Internal delay time due to brake relay:
330 ms with asynchronous
30 ms with synchronous motors
t8: Separation time of brake used, listed in relevant motor project
planning manual.
customerservice@hyperdynesystems.com | (479) 422-0390

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rexroth Indramat ECODRIVE03 Series and is the answer not in the manual?

Rexroth Indramat ECODRIVE03 Series Specifications

General IconGeneral
BrandRexroth Indramat
ModelECODRIVE03 Series
CategoryController
LanguageEnglish

Related product manuals