6-12 ECODRIVE03 Auxiliary Bleeder Module BZM01.3 ECODRIVE03 Drive Controllers
ZKS control supply
device-external device-internal
AP5304F1.FH7
bridge circuit
X2
1
2
3
4
5
6
7
8
10
11
12
ZKS1
+24Vpro
0V
ZKS2
9
Fig. 6-20: Connection +24V pro, 0V
At delivery with bridges at: X2.1 to X2.2
X2.7 to X2.8
Ap5184f1.fh7
R1
C1
Q
n
I
out
R1: approximately 50 R
C1: 100 µF
Fig. 6-21: Voltage source from X2.1
max. output voltage
(dependent of control voltage at X1.1)
voltage at X1.1 – 2V
A 1.0 CD:tnerruc tuptuo dewolla .xam
m 01htgnel dael dewolla .xam
retimil tnerruc gnigrahc aivnoitcetorp daolrevo lamreht
behind X1.1
A 4.2tnerruc tiucric trohs .xam
The connections supply current to the ZKS input.
Connection
+24V pro and 0V:
Output
+24V pro:
Loadability of the connection
+24Vpro:
Application
+24V pro: