No.
Definition
Symptom Possible Cause
390 B
TD sensor error
The BICU detects the TD sensor outputting
extraordinary voltage (less than 0.2 V or
more than 4.0 V) 10 times consecutively.
Defective TD sensor
Loose connection of the PCU
391 B
Development bias leak
The polling module detects a current leak
of the development bias.
Loose connection of the PCU
Defective high voltage supply board
392 B
Developer initialization error
The ID sensor does not detect a correct
pattern during developer initialization
(* 2-214-001).
Defective ID sensor
Insufficient developer
Defective drum operation
Defective development roller
operation
Loose connection of the PCU
Insufficient voltage for the charge
roller
401 B
Transfer roller leak error (positive electrode)
The feedback voltage of the transfer roller
is insufficient.
Defective high voltage supply board
Loose connection of the PCU
Incorrect installation of the transfer
unit or the separation unit
Defective transfer roller
402 B
Transfer roller leak error (negative electrode)
The feedback voltage of the transfer roller
is insufficient.
Defective high voltage supply board
Loose connection of the PCU
Incorrect installation of the transfer
unit or the separation unit
Defective transfer roller
500 B
Main motor error