No.
Definition
Symptom Possible Cause
The controller of the optional printer/
scanner is installed to one of the following
models:
• The MFP model
• The copier/facsimile model
• The printer/scanner/copier model
981 B
NVRAM error
An error occurs during engine NVRAM
check.
• Defective NVRAM
• Loose connection between the BICU
and the NVRAM
• Incorrect installation of the NVRAM
• Defective BICU
982 B
Localization error
The localization information in the
nonvolatile ROM and in the NVRAM is
different (* SP5-807-001).
• Localization setting not specified (The
main power switch is turned on for the
first time after the NVRAM is
replaced.)
• Incorrect localization setting
• Defective NVRAM
984 B
Print image transfer error
Print images are not transferred.
• Defective controller
• Defective BICU
• Loose connection between the
controller and the BICU
Service Call Conditions
115