:SYSTem:SYNC[:STATe]?
Description
Sets or queries the state of the on/off sync function.
Parameter
Name Type Range Default
<bool> Bool {0|1|ON|OFF} OFF
Remarks
For CH1 and CH2, the on/off state of one channel will change accordingly when
that of the other is modified.
The command is valid only when the tracking function (
:OUTPut:TRACk[:STATe]
)
is enabled.
Return Format
The query returns 1 or 0.
Examples
:SYST:SYNC ON /*Enables the on/off sync function.*/
:SYST:SYNC? /*Queries the state of the on/off sync function. The
query returns 1.*/
4.11.20 :SYSTem:TMODe
Syntax
:SYSTem:TMODe <
trackmode
>
:SYSTem:TMODe?
Description
Sets or queries the on/off state of tracking function.
Parameter
Name Type Range Default
<trackmode> Discrete {SYNC|INDE} INDE
Remarks
The tracking function is available for the specified channels (CH1 and CH2). You can
select the track mode as required. This command functions the same
as
:OUTPut:TRACk[:STATe]
.
Command System
98
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals