:TIMEr:GROUP:DELete 2 /*Deletes the 25th and 26th group of
parameters.*/
4.12.8 :TIMEr:RUN
Syntax
:TIMEr:RUN <
run
>
:TIMEr:RUN?
Description
Sets or queries the run type of the generator.
Parameter
Name Type Range Default
<run> Discrete {CONTinue|SINGle} CONTinue
Remarks
CONTinue: The instrument will output waveforms continuously according to the
number of groups and repetition cycle currently set when the waveform output
is enabled.
SINGle: The instrument will output a single set of data in order each time the
waveform output is enabled.
Return Format
The query returns CONTINUE or SINGLE.
Examples
:TIMEr:RUN SINGle /*Sets the run type to single.*/
:TIMEr:RUN? /*Queries the run type. The query returns SINGle.*/
4.12.9 :TIMEr[:STATe]
Syntax
:TIMEr[:STATe] <
bool
>
:TIMEr[:STATe]?
Description
Sets or queries the run/stop state of the generator.
Command System
106
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.