Name Type Range Default
<bool> Bool {0|1|ON|OFF} 0
Remarks
For the two channels (CH1 and CH2) that support this mode, changes made on
one channel (voltage/current setting value, OVP/OCP level and on/off status) are
applied to the other channel.
By default, the tracking function is disabled. It is usually used to provide
symmetric voltage for the operational amplifier or other circuits.
The tracking function only tracks the voltage/current setting value. The actual
output voltage/current will not be affected.
Return Format
The query returns 1 or 0.
Examples
:OUTP:TRAC ON /*Enables the tracking function for CH2.*/
:OUTP:TRAC? /*Queries the on/off state of the tracking function.
The query returns 1.*/
4.9 :SOURce Commands
:SOURce commands are used to set the voltage, current, OVP, and OCP of the
specified channel. While the :APPLy command offers the most straightforward
method to program the power supply via remote interfaces, :SOURce commands give
you more flexibility to change individual parameters.
4.9.1 [:SOURce[<n>]]:CURRent[:LEVel][:IMMediate]
[:AMPLitude]
Syntax
[:SOURce[<
n
>]]:CURRent[:LEVel][:IMMediate][:AMPLitude] {<
current
>|
<
lim
>|<
amp
>}
[:SOURce[<
n
>]]:CURRent[:LEVel][:IMMediate][:AMPLitude]? [<
lim
>]
Description
Sets or queries the current of the specified channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
57

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals